首页> 外文期刊>Optical engineering >High-temperature digital image correlation method for full-field deformation measurement captured with filters at 2600℃ using spraying to form speckle patterns
【24h】

High-temperature digital image correlation method for full-field deformation measurement captured with filters at 2600℃ using spraying to form speckle patterns

机译:高温数字图像相关法用于全场形变测量,在2600℃的条件下用过滤器通过喷涂形成斑点图案

获取原文
获取原文并翻译 | 示例
       

摘要

A method is presented for obtaining good images of a sprayed speckle pattern on specimen surfaces at high temperatures, suitable for strain measurement, by digital image correlation (DIC) using plasma spray for speckle preparation in which a bandpass filter, neutral density filters, and a linear polarizing filter are used to reduce intensity and noise in images. This is accomplished by speckle preparation through the use of plasma spray and suppression of black-body radiation through the use of filters. By using plasma spray for speckle preparation and the filters for image acquisition, the method was demonstrated to be capable of providing accurate DIC measurements up to 2600℃. The full-field stretching deformation of the specimen was determined using the DIC technique. Experimental results indicate that the proposed high-temperature DIC method is easy to implement and can be applied to practical, full-field, high-temperature deformation measurements with high accuracy.
机译:提出了一种方法,该方法通过使用等离子体喷涂进行斑点制备的数字图像相关(DIC),在高温下获得适用于应变测量的样品表面喷涂斑点图案的良好图像,其中带通滤光片,中性密度滤光片和线性偏振滤镜用于降低图像的强度和噪声。这是通过使用等离子喷涂进行斑点准备,以及通过使用滤镜来抑制黑体辐射来实现的。通过使用等离子喷涂进行斑点制备和使用滤光片进行图像采集,该方法被证明能够提供高达2600℃的准确DIC测量。使用DIC技术确定样品的全视野拉伸变形。实验结果表明,所提出的高温DIC方法易于实现,可以高精度,实用地应用于全场高温变形测量中。

著录项

  • 来源
    《Optical engineering》 |2014年第6期|063101.1-063101.12|共12页
  • 作者单位

    Xi'an Jiaotong University, School of Mechanical Engineering, No. 28 Xianning Road, Xi'an, Shaanxi Province 710049, China Xi'an Jiaotong University, State Key Laboratory for Manufacturing Systems Engineering, No. 28 Xianning Road, Xi'an, Shaanxi Province, China;

    Xi'an Jiaotong University, School of Mechanical Engineering, No. 28 Xianning Road, Xi'an, Shaanxi Province 710049, China Xi'an Jiaotong University, State Key Laboratory for Manufacturing Systems Engineering, No. 28 Xianning Road, Xi'an, Shaanxi Province, China;

    Xi'an Jiaotong University, School of Mechanical Engineering, No. 28 Xianning Road, Xi'an, Shaanxi Province 710049, China Xi'an Jiaotong University, State Key Laboratory for Manufacturing Systems Engineering, No. 28 Xianning Road, Xi'an, Shaanxi Province, China;

    Xi'an Jiaotong University, School of Mechanical Engineering, No. 28 Xianning Road, Xi'an, Shaanxi Province 710049, China Xi'an Jiaotong University, State Key Laboratory for Manufacturing Systems Engineering, No. 28 Xianning Road, Xi'an, Shaanxi Province, China;

    Xi'an Jiaotong University, School of Mechanical Engineering, No. 28 Xianning Road, Xi'an, Shaanxi Province 710049, China Xi'an Jiaotong University, State Key Laboratory for Manufacturing Systems Engineering, No. 28 Xianning Road, Xi'an, Shaanxi Province, China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    high-temperature measurement; digital image correlation; sprayed speckle pattern;