首页> 外文期刊>Optical engineering >Design and analysis of a multi-element dual band infrared detector for counter-countermeasure
【24h】

Design and analysis of a multi-element dual band infrared detector for counter-countermeasure

机译:一种用于对抗的多元素双波段红外探测器的设计与分析

获取原文
获取原文并翻译 | 示例
           

摘要

A dual band multi-element infrared (IR) detector which enables effective target tracking in a complex tactical environment is presented. The photosensitive elements are designed like the stripes of the Lovell optical reticle and arranged close to each other. The thin films of the dual band filter are precisely coated onto an IR transparent substrate, which is then bonded directly onto the surface of photosensitive area with an IR transparent adhesive. The optical system of the detector adopts a spin-scan mode. The filter-detector combination rotates with a mechanical rotor during scanning. The dual band filters temporally encode target location into the incoming radiation signals, and the photosensitive elements then convert the modulated radiation into an electrical signal. The ratio of radiation intensity from two bands can be calculated to distinguish target from IR target-flare mixed signals. Because the pattern of the detector is similar to the Lovell reticle, the detector can also perform spatial filtering to eliminate background noise. In addition, relatively high stability, together with simplicity of the hardware and low cost, indicates that the presented method has a potential application at the field in which precision is not strictly requested.
机译:提出了一种双波段多元素红外(IR)检测器,它能够在复杂的战术环境中进行有效的目标跟踪。感光元件被设计成像洛威尔光学掩模版的条纹一样并且彼此靠近布置。将双带滤光片的薄膜精确地涂覆在IR透明基板上,然后使用IR透明粘合剂将其直接粘合到光敏区域的表面上。检测器的光学系统采用自旋扫描模式。过滤器-检测器组合在扫描过程中与机械转子一起旋转。双波段滤波器将目标位置暂时编码为入射辐射信号,然后光敏元件将调制后的辐射转换为电信号。可以计算两个波段的辐射强度之比,以将目标与IR目标耀斑混合信号区分开。因为检测器的图案类似于Lovell掩模版,所以检测器还可以执行空间滤波以消除背景噪声。另外,相对较高的稳定性,以及硬件的简单性和低成本,表明所提出的方法在不严格要求精度的领域中具有潜在的应用。

著录项

  • 来源
    《Optical engineering》 |2014年第1期|013101.1-013101.7|共7页
  • 作者

    Weiguo Sun; Mo Li; Hongxu Chen;

  • 作者单位

    Luoyang Optoelectronic Technology Development Centre, PO Box 030, Luoyang Henan 471009, China;

    Luoyang Optoelectronic Technology Development Centre, PO Box 030, Luoyang Henan 471009, China;

    Luoyang Optoelectronic Technology Development Centre, PO Box 030, Luoyang Henan 471009, China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    counter-countermeasure; dual band; spatial filtering; multi-element; infrared detector;

    机译:反措施;双频;空间过滤;多元素红外探测器;