In this paper, we demonstrated a trace double-component gas detection system based on frequency division multiplexing using two-way distributed feedback laser diode (DFB-LD) as the excitation laser source. In the frequency response range of photoacoustic spectroscopy (PAS) cell, this detection system could detect the second harmonics of different frequencies f(0) and f(1), which were excited by the gas absorption using the two wavelengths of DFB-LD at modulation frequencies f(0)/2 and f(1)/2. Unlike previous double-component gas sensor, these two DFB-LDs connected into the both ends of PAS cell without optical fiber coupler could effectively improve the excited light intensity and simplify the system structure. This feature allowed the trace detection of double-component gas of mixed-methane (CH4) and water (H2O) vapor with a low detection limits 11.055ppm and 885ppb, respectively. Additionally, the linear responses to the gas concentration were achieved 0.9986 and 0.9997, and it exhibited potentially as an effective detection system for complex gas component.
机译:在本文中,我们用双向分布式反馈激光二极管(DFB-LD)作为激发激光源,证明了一种基于频分复用的迹线双组分气体检测系统。在光声光谱(PAS)电池的频率响应范围内,该检测系统可以检测不同频率f(0)和f(1)的第二谐波,其通过使用两个波长的DFB-LD在的气体吸收激发调制频率f(0)/ 2和f(1)/ 2。与之前的双组分气体传感器不同,这两个DFB-LD连接到没有光纤耦合器的PAS电池的两端,可以有效地提高激发的光强度并简化系统结构。该特征允许痕量检测混合甲烷(CH4)和水(H2O)蒸汽的双组分气体,分别具有低检测限值11.055ppm和885ppb。另外,对气体浓度的线性响应得到0.9986和0.9997,其潜在地作为复杂气体组分的有效检测系统。

著录项

  • 来源
    《Optical and quantum electronics》 |2019年第8期|268.1-268.8|共8页
  • 作者单位

    Liaocheng Univ Sch Phys Sci & Informat Technol Liaocheng 252059 Shandong Peoples R China|Liaocheng Univ Shandong Key Lab Opt Commun Sci & Technol Liaocheng 252059 Shandong Peoples R China;

    Liaocheng Univ Sch Phys Sci & Informat Technol Liaocheng 252059 Shandong Peoples R China|Liaocheng Univ Shandong Key Lab Opt Commun Sci & Technol Liaocheng 252059 Shandong Peoples R China;

    Liaocheng Univ Sch Phys Sci & Informat Technol Liaocheng 252059 Shandong Peoples R China|Liaocheng Univ Shandong Key Lab Opt Commun Sci & Technol Liaocheng 252059 Shandong Peoples R China;

    Liaocheng Univ Sch Phys Sci & Informat Technol Liaocheng 252059 Shandong Peoples R China|Liaocheng Univ Shandong Key Lab Opt Commun Sci & Technol Liaocheng 252059 Shandong Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Double-component gas detection; Photoacoustic spectroscopy; Two-way distributed feedback laser diode; Frequency division multiplexing;

    机译:双组分气体检测;光声光谱;双向分布式反馈激光二极管;频分复用;