首页> 外文期刊>Nuclear Technology >VALIDATION OF MONTE CARLO SIMULATION OF A THYROID UPTAKE SYSTEM USING VARIOUS SOURCES AND A SLAB PHANTOM
【24h】

VALIDATION OF MONTE CARLO SIMULATION OF A THYROID UPTAKE SYSTEM USING VARIOUS SOURCES AND A SLAB PHANTOM

机译:利用各种源和平板幻影验证甲状腺摄取系统的蒙特卡罗模拟

获取原文
获取原文并翻译 | 示例
       

摘要

In the event of a terrorist act involving a radiological agent, internal contamination due to inhalation is a potential health threat. When a large population is potentially impacted, there is need for methodology to serve as an initial screening or triage tool to rapidly identify individuals with significant amounts of internal contamination and to assist in prioritizing collection of large numbers of bioassay samples needed in such an incident. Common handheld radiation detectors and medical devices are tools that can effectively and rapidly screen a large number of people for internal contamination due to gamma-emitting isotopes. This work investigated the usernof a common medical device, a thyroid uptake system or thyroid probe, in screening for internal contamination in individuals. The response of a thyroid uptake system in such a situation can be estimated by using a validated Monte Carlo model of the thyroid uptake system and various human phantoms. A computational model of the thyroid uptake system was built using the Los Alamos Particle Transport Code, MCNP Version 5. The validation of this computational model was demonstrated by comparisons to a series of benchmark measurements using the actual device and six isotopes with a range of gamma-ray emission energies.
机译:如果发生涉及放射媒介的恐怖行为,则由于吸入引起的内部污染可能对健康造成威胁。当大量人口可能受到影响时,需要一种方法作为初始筛查或分类工具,以快速识别具有大量内部污染的个体,并帮助确定此类事件所需的大量生物测定样品的优先级。普通的手持式辐射探测器和医疗设备是可以有效且快速地筛查大量人员是否存在因发射伽马射线的同位素引起的内部污染的工具。这项工作调查了常见医疗设备,甲状腺吸收系统或甲状腺探针的使用者,以筛查个体内部污染。可以通过使用经过验证的甲状腺摄取系统和各种人体模型的蒙特卡洛模型来估计这种情况下的甲状腺摄取系统的反应。使用《洛斯阿拉莫斯颗粒运输法》(MCNP版本5)建立了甲状腺吸收系统的计算模型。通过与一系列使用实际装置和六个同位素以及一系列伽马值的基准测量值进行比较,证明了该计算模型的有效性。射线发射能量。

著录项

  • 来源
    《Nuclear Technology》 |2009年第1期|169-172|共4页
  • 作者单位

    Georgia Institute of Technology, 900 Atlantic Drive, Atlanta, Georgia 30332;

    Georgia Institute of Technology, 900 Atlantic Drive, Atlanta, Georgia 30332;

    Georgia Institute of Technology, 900 Atlantic Drive, Atlanta, Georgia 30332;

    University of Texas, MD Anderson Cancer Center Houston, Texas;

    Centers for Disease Control and Prevention Radiation Studies Branch, Atlanta, Georgia;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    thyroid uptake system; radiological dispersal device; internal contamination;

    机译:甲状腺摄取系统;放射扩散装置;内部污染;
  • 入库时间 2022-08-18 00:44:13