A condensation experiment in the presence of non- condensable gas in a vertical tube of the passive con- tainment cooling system of the CP-1300 is performed. The experimental results show that the heat transfer co- Efficients (HTCs) increase as the inlet air mass fraction Decreases and the inlet saturated steam temperature de- Creases. However, the dependence of the inlet mixture Reynolds number on the HTC is small for the operating Range. An empirical correlation is developed, and its Predictions are compared with experimental data to show Good agreement with the standard deviation of 22.3/100.
机译:在CP-1300的被动式防护冷却系统的垂直管中存在不可冷凝气体的条件下进行了冷凝实验。实验结果表明,传热系数(HTC)随着入口空气质量分数的降低和入口饱和蒸汽温度的降低而增加。但是,对于运行范围,进气混合物雷诺数对HTC的依赖性很小。建立了经验相关性,并将其预测值与实验数据进行比较,显示出良好的一致性,标准偏差为22.3 / 100。