...
首页> 外文期刊>Nuclear Instruments & Methods in Physics Research. B, Beam Interactions with Materials and Atoms >Bioanalysis works in the IAA AMS facility: Comparison of AMS analytical method with LSC method in human mass balance study
【24h】

Bioanalysis works in the IAA AMS facility: Comparison of AMS analytical method with LSC method in human mass balance study

机译:在IAA AMS设施中进行生物分析:人体质量平衡研究中AMS分析方法与LSC方法的比较

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Institute of Accelerator Analysis Ltd. (IAA) is the first Contract Research Organization in Japan providing Accelerator Mass Spec-trometry (AMS) analysis services for carbon dating and bioanalysis works. The 3 MV AMS machines are maintained by validated analysis methods using multiple control compounds. It is confirmed that these AMS systems have reliabilities and sensitivities enough for each objective. The graphitization of samples for bioanalysis is prepared by our own purification lines including the measurement of total carbon content in the sample automatically. In this paper, we present the use of AMS analysis in human mass balance and metabolism profiling studies with IAA 3 MV AMS, comparing results obtained from the same samples with liquid scintillation counting (LSC). Human samples such as plasma, urine and feces were obtained from four healthy volunteers orally administered a ~(14)C-labeled drug Y-700, a novel xanthine oxidase inhibitor, of which radioactivity was about 3 MBq (85 μCi). For AMS measurement, these samples were diluted 100-10,000-fold with pure-water or blank samples. The results indicated that AMS method had a good correlation with LSC method (e.g. plasma: r = 0.998, urine: r = 0.997, feces: r = 0.997), and that the drug recovery in the excreta exceeded 92%. The metabolite profiles of plasma, urine and feces obtained with HPLC-AMS corresponded to radio-HPLC results measured at much higher radioactivity level. These results revealed that AMS analysis at IAA is useful to measure ~(14)C-concentration in bioanalysis studies at very low radioactivity level.
机译:加速器分析有限公司(IAA)是日本第一个合同研究组织,为碳定年和生物分析工作提供加速器质谱(AMS)分析服务。 3 MV AMS机器通过使用多种控制化合物的有效分析方法进行维护。可以肯定的是,这些AMS系统对于每个目标都具有足够的可靠性和敏感性。用于生物分析的样品的石墨化是通过我们自己的纯化线准备的,包括自动测量样品中的总碳含量。在本文中,我们介绍了AMS分析在使用IAA 3 MV AMS进行的人体质量平衡和代谢谱研究中的用途,并使用液体闪烁计数(LSC)比较了从相同样品中获得的结果。血浆,尿液和粪便等人体样品来自四名健康志愿者,口服了〜(14)C标记的药物Y-700,这是一种新型的黄嘌呤氧化酶抑制剂,其放射性约为3 MBq(85μCi)。对于AMS测量,这些样品用纯水或空白样品稀释100-10,000倍。结果表明AMS方法与LSC方法具有良好的相关性(例如血浆:r = 0.998,尿液:r = 0.997,粪便:r = 0.997),排泄物中的药物回收率超过92%。用HPLC-AMS获得的血浆,尿液和粪便的代谢产物图谱与在高得多的放射性水平下测得的放射性HPLC结果相对应。这些结果表明,IAA的AMS分析可用于在非常低的放射性水平下测量生物分析研究中的〜(14)C浓度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号