Computed tomography for light materials using a monochromatic X-ray beam produced by parametric X-ray radiation

机译:使用X射线参数化产生的单色X射线对轻质材料进行计算机断层扫描

获取原文
获取原文并翻译 | 示例

摘要

Computed tomography (CT) for light materials such as soft biological tissues was performed using a monochromatic X-ray beam provided by a parametric X-ray radiation (PXR) source at the Laboratory for Electron Beam Research and Application (LEBRA) of Nihon University. Using a high-efficiency flat panel detector (FPD), each projection image for CT was taken with exposure times of 5 or 10 s, and 60-360 projection images in each run were obtained with total measurement time of 5 min to 1 h. CT images were obtained from the projection images using the conventional calculation method. The typical tomograms obtained had sharp outlines, which are likely attributable to the propagation-based phase contrast.
机译:使用日本大学电子束研究与应用实验室(LEBRA)的参数X射线辐射(PXR)源提供的单色X射线束,对诸如软生物组织之类的轻材料进行计算机断层扫描(CT)。使用高效平板检测器(FPD),以5或10 s的曝光时间拍摄每个CT的投影图像,并以5分钟至1 h的总测量时间获得每次运行的60-360个投影图像。使用常规计算方法从投影图像获得CT图像。获得的典型断层图具有清晰的轮廓,这很可能归因于基于传播的相衬。

著录项

  • 来源
  • 作者单位

    Laboratory for Electron Beam Research and Application, Ninon University, Narashinodai 7-24-1, Funabashi 274-8501, Japan;

    Laboratory for Electron Beam Research and Application, Ninon University, Narashinodai 7-24-1, Funabashi 274-8501, Japan;

    Laboratory for Electron Beam Research and Application, Ninon University, Narashinodai 7-24-1, Funabashi 274-8501, Japan;

    Nihon University School of Dentistry at Matsudo, Sakaecho-Nishi 2-870-1, Matsudo 271-8587, Japan;

    Laboratory for Electron Beam Research and Application, Ninon University, Narashinodai 7-24-1, Funabashi 274-8501, Japan;

    Laboratory for Electron Beam Research and Application, Ninon University, Narashinodai 7-24-1, Funabashi 274-8501, Japan;

    Nihon University School of Dentistry at Matsudo, Sakaecho-Nishi 2-870-1, Matsudo 271-8587, Japan;

    Laboratory for Electron Beam Research and Application, Ninon University, Narashinodai 7-24-1, Funabashi 274-8501, Japan;

    Laboratory for Electron Beam Research and Application, Ninon University, Narashinodai 7-24-1, Funabashi 274-8501, Japan;

    Nihon University School of Dentistry at Matsudo, Sakaecho-Nishi 2-870-1, Matsudo 271-8587, Japan;

    Laboratory for Electron Beam Research and Application, Ninon University, Narashinodai 7-24-1, Funabashi 274-8501, Japan;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Novel X-ray source; Monochromatic X-ray; X-ray imaging; Computed tomography; Parametric X-ray radiation;

    机译:新颖的X射线源;单色X射线X射线成像;CT检查;参数X射线辐射;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号