首页> 外文期刊>Nuclear Instruments & Methods in Physics Research. B, Beam Interactions with Materials and Atoms >Application of radiochromic film for quality assurance in the heavy-ion beam scanning irradiation system at HIMAC
【24h】

Application of radiochromic film for quality assurance in the heavy-ion beam scanning irradiation system at HIMAC

机译:放射性变色膜在HIMAC重离子束扫描辐照系统中的质量保证应用

获取原文
获取原文并翻译 | 示例
           

摘要

For the quality assurance (QA) of therapeutic scanned carbon-ion beams, QA tool having high spatial resolution is required. The radiochromic film (such as Gafchromic EBT2 film model) is a very useful tool because of its high spatial resolution, self-development, and near tissue equivalence. However, for a complex field in carbon-ion therapy, it is difficult to unambiguously determine the dose from the measured net optical density (OD). As a first approach, we investigated the response of EBT2 to carbon-ion beam at the Heavy Ion Medical Accelerator in Chiba (HIMAC) in Japan. Based on the measured results, we performed QA measurements independently of dose. We verified the QA measurements by EBT2 by comparing the ionization chamber and the fluorescent screen. The results obtained with EBT2 were in good agreement with those obtained with the other detector. In addition, to test the use in a complex field, we verified the OD distributions for moving and static target by means of a gamma index analysis. As a result, we confirmed that EBT2 could be used as a part of QA procedures for therapeutic scanned carbon-ion beams.
机译:为了治疗性扫描碳离子束的质量保证(QA),需要具有高空间分辨率的QA工具。放射致变色胶片(例如Gafchromic EBT2胶片模型)是一种非常有用的工具,因为它具有较高的空间分辨率,自身显影能力和接近组织的等效性。然而,对于碳离子治疗中的复杂领域,很难根据测得的净光密度(OD)明确确定剂量。作为第一种方法,我们在日本千叶县重离子医学加速器(HIMAC)上研究了EBT2对碳离子束的响应。根据测量结果,我们独立于剂量执行QA测量。通过比较电离室和荧光屏,我们通过EBT2验证了QA测量。用EBT2获得的结果与使用其他检测器获得的结果非常一致。此外,为了测试在复杂领域中的使用,我们通过伽玛指数分析验证了移动和静态目标的OD分布。结果,我们确认EBT2可以用作治疗性碳离子束QA程序的一部分。

著录项

  • 来源
  • 作者单位

    Medical Physics Research Group, Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan;

    Medical Physics Research Group, Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan;

    Medical Physics Research Group, Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan;

    Medical Physics Research Group, Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan;

    Medical Physics Research Group, Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan;

    Medical Physics Research Group, Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Particle therapy; Scanning irradiation; Gafchromic EBT2 film; Quality assurance;

    机译:粒子疗法;扫描照射;全色EBT2膜;质量保证;