Detection of sub micro Gray doses finds application in personnel and environmental monitoring, and nuclear forensics. Recently developed LiMgPO_4:Tb,B (LMP) is highly sensitive Optically Stimulated Luminescence (OSL) phosphor with excellent dosimetric properties. The OSL emission spectrum of LMP consists of several peaks attributed to characteristic Tb~(3+) emission. The OSL emission peak at 380 nm is favorable for bi-alkali PMT used in RISO reader system. It is demonstrated that significant improvement in dose detection threshold can be realized for LMP by optimization of continuous wave (CW-) OSL parameters like stimulation intensity and readout time. The minimum measurable dose (MMD) as low as 0.49 μGy in readout time of less than 1 s at stimulation intensity of 32 mW/cm2 has been achieved using this phosphor. The recommendations for choice of parameters for personnel and environmental monitoring are also discussed.
机译:亚微米灰色剂量的检测可用于人员和环境监测以及核法证学。最近开发的LiMgPO_4:Tb,B(LMP)是具有出色的剂量特性的高度敏感的光学激发发光(OSL)荧光粉。 LMP的OSL发射光谱由归因于特征性Tb〜(3+)发射的几个峰组成。 380 nm处的OSL发射峰对于RISO读取器系统中使用的双碱PMT是有利的。通过优化连续波(CW-)OSL参数(如刺激强度和读出时间),可以证明LMP可以显着提高剂量检测阈值。使用这种荧光粉,在32 mW / cm2的刺激强度下,在不到1 s的读出时间内,最小可测量剂量(MMD)达到0.49μGy。还讨论了有关人员和环境监测参数选择的建议。