The start of operation of a new separator ACCULINNA-2 makes an important upgrade for the Radioactive-Ion Beam (RIB) research done at the Flerov Laboratory of Nuclear Reactions (FLNR, JINR). Test results indicate that the separator meets the project specifications. Intensities obtained for the ~(6,8)He, ~(9,11)Li, ~(12)Be RIBs are 15 times higher in comparison with the results achieved at the old separator ACCULINNA. An overview of the design, construction and commissioning studies of the ACCULINNA-2 separator is presented. The separator will be equipped with some key facilities: a cryogenic tritium target, zero degree spectrometer following the physical target bombarded by the RIBs, and with a neutron detector array, and the Time Projection Chamber (TPC). This opens a wide range of experimental possibilities. Overview is presented on the two first experiments devoted to the study of d + ~6He elastic scattering and search for a ~7H low-lying resonance state populated in the ~2H (~8He,~3He)~7H reaction.
机译:新分离器ACCULINNA-2的开始运行,是弗莱罗夫核反应实验室(FLNR,JINR)进行的放射性离子束(RIB)研究的重要升级。测试结果表明分离器符合项目规格。 〜(6,8)He,〜(9,11)Li,〜(12)Be RIB的强度是旧隔板ACCULINNA的15倍。介绍了ACCULINNA-2分离器的设计,构造和调试研究。分离器将配备一些关键设施:低温tri靶,跟随RIB轰击的物理靶的零度光谱仪,中子探测器阵列以及时间投影室(TPC)。这开辟了广泛的实验可能性。概述了第一个致力于d +〜6He弹性散射和寻找〜2H(〜8He,〜3He)〜7H反应的〜7H低共振态的实验。