The central tracking detector of the ZEUS experiment has been in operation since 1992. It is a cylindrical drift chamber, approximately 2m in length and 1 m in diameter, and has operated reliably in a magnetic field of 1.43 T using agas mixture of 83:12:5 argon/CO_2/ethane with a trace (~0.5%) of ethanol. Initial studies conducted between 1995 and 2000 using dE/dx to search for a long-term loss of gain were inconclusive. During the course of 2000, operational problems caused by repeated trips of high-voltage in the outer superlayers of the detector were experienced. These were attributed to the Malter effect, which has shown to be alleviated by the addition of water to the gas mixture. Consequently, a trace of water (~0.15%) was added to the gas and has, to date, proved to be a successful remedy. Changes in the chamber performance due to the additional water are covered and solutions to the problems encountered are detailed.
机译:ZEUS实验的中央跟踪检测器自1992年以来一直在运行。它是一个圆柱形的漂移室,长约2m,直径约1m,并且使用83:12的混合气体在1.43 T的磁场中可靠运行:5氩气/ CO_2 /乙烷,含痕量乙醇(约0.5%)。 1995年至2000年间使用dE / dx进行的初步研究尚无定论,该研究旨在寻找长期的增益损失。在2000年的过程中,遇到了由于探测器外层中的高电压反复跳闸而引起的操作问题。这些归因于马尔特效应,通过向混合气体中加水可以缓解这种效应。因此,向气体中加入了微量水(〜0.15%),迄今为止,已证明是成功的补救方法。涵盖了由于添加水而导致的腔室性能变化,并详细介绍了所遇到问题的解决方案。