Aging study for resistive plate chambers of the CMS muon trigger detector

机译:CMSμon触发探测器电阻板腔的老化研究

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

A long-term aging test of a Resistive Plate Chamber (RPC) was carried out with an intense gamma ~(137)Cs source. The detector was operated in avalanche mode and had the bakelite surface treated with linseed oil. After the irradiation the estimated dose, charge and fluence were approximately equal to the expected values after 10 years of operation in the CMS barrel region. During and after the irradiation, the RPC performance was monitored with cosmic muons and showed no relevant aging effects. Moreover, no variation of the bakelite resistance was observed.
机译:电阻板腔(RPC)的长期老化测试是使用强烈的γ〜(137)Cs源进行的。该检测器以雪崩模式运行,并用亚麻子油处理了胶木表面。辐照后,在CMS镜筒区域工作10年后,估计剂量,电荷和通量大约等于预期值。在辐照期间和辐照之后,用宇宙介子对RPC性能进行了监测,未发现相关的老化效应。此外,未观察到电木电阻的变化。