首页> 外文期刊>Nuclear Instruments & Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment >Radiation hardness, excess noise factor and short-term gain instability of vacuum phototriodes for the operation in pseudorapidity range 1.5 ≤η≤ 3.0 at CMS ECAL Yu.
【24h】

Radiation hardness, excess noise factor and short-term gain instability of vacuum phototriodes for the operation in pseudorapidity range 1.5 ≤η≤ 3.0 at CMS ECAL Yu.

机译:在CMS ECAL Yu上,在伪快速范围为1.5≤η≤3.0的条件下操作的真空光电三极管的辐射硬度,超额噪声因子和短期增益不稳定性。

获取原文
获取原文并翻译 | 示例

摘要

The operation of super radiation hard prototypes of vacuum fine-mesh phototriodes (VPT) proposed for application in CMS Endcap ECAL at the pseudorapidity of η≥ 2.6 has been investigated in radiation fields up to 50 kGy and neutron fluence of 7 x 1015 neutron cm~(-2). It is shown that anode response and the excess noise factor of VPT are independent of given above radiation dose and neutron fluence. The results of VPT gain variation measurements under rapid changes of counting rate are presented for the operation in the pseudorapidity range 1.5 ≤η≤ 3.0.
机译:在高达50 kGy的辐射场和中子注量为7 x 1015 cm的辐射场中研究了拟用于CMS Endcap ECAL的CMS细端光电三极管(VCAP)的超辐射硬原型的操作,该伪快度为η≥2.6。 (-2)。结果表明,阳极响应和VPT的超额噪声因子与给定的上述辐射剂量和中子注量无关。给出了在伪快速范围1.5≤η≤3.0下操作时,计数率快速变化时VPT增益变化的测量结果。