We present the detailed analysis of the time and charge signals of a prototype double gap resistive plate chamber for the endcap region of the compact muon solenoid detector at CERN LHC. We demonstrate that the operating high-voltage plateau can be extended at least up to 400 V with the present design. The simple avalanche multiplication model can reproduce the experimental charge spectra reasonably well at the beginning of the high-voltage plateau region. The effective Townsend coefficient is estimated in the avalanche mode operation.
机译:我们对CERN LHC紧凑型μ介子螺线管探测器的端盖区域的原型双间隙电阻板腔的时间和电荷信号进行了详细分析。我们证明,使用本设计,工作高压平稳区至少可以扩展到400V。简单的雪崩倍增模型可以在高压高原区域的开始部分合理地再现实验电荷谱。有效的汤森系数在雪崩模式操作中估算。