首页> 外文期刊>Nuclear Instruments & Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment >Effect of spatial coherence on application of in-line phase contrast imaging to synchrotron radiation mammography
【24h】

Effect of spatial coherence on application of in-line phase contrast imaging to synchrotron radiation mammography

机译:空间相干对在线相衬成像在同步辐射乳腺摄影中的应用的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Effect of spatial coherence on the application of in-line phase contrast imaging (IL-PCI) to synchrotron radiation (SR) mammography is investigated experimentally at SYRMEP/ELETTRA. Factors that are related to spatial coherence and IL-PCI image quality, which include vertical and horizontal beam, photon energy, slit width, sample-detector distance and detector resolution, are analyzed. The experimental results demonstrate that better IL-PCI image quality could be achieved in the vertical beam. As for the slit width, the spatial coherence for horizontal beam remains almost the same until the slit width is gradually closed to 5 mm. For mammography applications of IL-PCI, slit width of 100mm could be employed and high-enough image quality can still be obtained. Lower photon energy results in better coherence and correspondingly better IL-PCI image quality. By compromising the dose and image quality, photon energy of ~19 keV is recommended for SR mammography. To preserve the edge enhancement resulting from good coherence of SR, an appropriate sample-detector distance and a practical detector should be selected. The optimum sample-detector distance highly depends on detector resolution. For high-resolution film, the best IL-PCI imaging quality is obtained at a closer sample-detector distance. For an X-ray CCD with pixel size of 14 μm, about 1.5 m is needed to achieve optimum image quality. The large pixel size of the detector will deteriorate the edge-enhancing efficiency and results in lower IL-PCI imaging quality. In practice, the spatial resolution and sensitivity of the detectors should be compromised.
机译:在SYRMEP / ELETTRA上,实验研究了空间相干性对在线相衬成像(IL-PCI)在同步辐射(SR)乳腺摄影中的应用的影响。分析了与空间相干性和IL-PCI图像质量有关的因素,包括垂直和水平光束,光子能量,狭缝宽度,样品检测器距离和检测器分辨率。实验结果表明,在垂直光束中可以获得更好的IL-PCI图像质量。至于缝隙宽度,直到缝隙宽度逐渐减小到5 mm为止,水平光束的空间相干性几乎保持不变。对于IL-PCI的乳腺摄影应用,可以采用100mm的狭缝宽度,并且仍然可以获得足够高的图像质量。较低的光子能量会导致更好的相干性,并相应改善IL-PCI图像质量。通过牺牲剂量和图像质量,建议将〜19 keV的光子能量用于SR乳腺摄影。为了保留由于SR的良好相干性而导致的边缘增强,应选择适当的样本检测器距离和实用的检测器。最佳的样品检测器距离很大程度上取决于检测器的分辨率。对于高分辨率胶片,在更近的样品检测器距离处可获得最佳的IL-PCI成像质量。对于像素尺寸为14μm的X射线CCD,需要约1.5 m才能获得最佳图像质量。检测器的大像素尺寸会降低边缘增强效率,并导致较低的IL-PCI成像质量。在实践中,探测器的空间分辨率和灵敏度应受到影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号