A new gas distribution and monitoring system was installed as part of an upgrade of the forward endcap muon detection system (IFR) of the BaBar detector at SLAC. Over 300 gas circuits are controlled and monitored. The return gas flow is monitored by digital bubblers which use photo-gate electronics to count the bubbling rate. The rates are monitored in real time and recorded in a history database allowing studies of flow rate versus chamber performance. (C) 2004 Elsevier B.V. All rights reserved.
机译:在SLAC的BaBar探测器的前端电容μ子探测系统(IFR)的升级中,安装了新的气体分配和监视系统。超过300个气体回路受到控制和监视。返回的气体流量由数字起泡器监控,该起泡器使用光电门电子设备来计算起泡率。实时监控流量,并将其记录在历史数据库中,以研究流量与腔室性能之间的关系。 (C)2004 Elsevier B.V.保留所有权利。