【24h】

Scintillation properties and radioactive contamination of CaWO4 crystal scintillators

机译:CaWO4晶体闪烁体的闪烁特性和放射性污染

获取原文
获取原文并翻译 | 示例

摘要

Energy resolution, alpha/beta ratio and the pulse-shape discrimination ability of the CaWO4 crystal scintillators were studied. The radioactive contamination and background of the crystals were measured in the Solotvina Underground Laboratory. Despite a rather high level of radioactive impurities, the background rate of the CaWO4 detector in the energy window of the Ca-48 neutrinoless 2beta decay (3.6-5.4 MeV) was reduced to 0.07 counts/(yr keV kg). The indication for a decay of W-180 (Phys. Rev. 67 (2003) 014310) was confirmed (the measured half-life is T-1/2 = 1.0(-0.3)(+0.7) x 10(18)yr). (C) 2004 Elsevier B.V. All rights reserved.
机译:研究了CaWO4晶体闪烁体的能量分辨率,α/β比和脉冲形判别能力。在Solotvina地下实验室测量了晶体的放射性污染和本底。尽管放射性杂质含量很高,但Ca-48无中微子2β衰变(3.6-5.4 MeV)的能量窗口中的CaWO4检测器的本底率降低到0.07计数/(yr keV kg)。确认了W-180的衰变迹象(Phys。Rev. 67(2003)014310)(测得的半衰期为T-1 / 2 = 1.0(-0.3)(+ 0.7)x 10(18)yr )。 (C)2004 Elsevier B.V.保留所有权利。