The 60 MeV proton beam delivered by the RADEF facility of the University of Jyvaeskylae (Finland) was used to measure the radiation effects on the counter components of the V0 detector of ALICE. There are the scintillator BC404, the wavelength shifting fibres BCF9929A and the optical fibres BCF98 from Bicron (Saint-Gobain). The light yield and the time resolution given by a counter of the inner ring of the V0C array, mounted within a dedicated device, were measured as a function of the radiation dose up to about 300 krad. A global light attenuation of the order of 30% can be anticipated during 10 years of ALICE running.
机译:于韦斯屈莱大学(芬兰)的RADEF设施提供的60 MeV质子束用于测量辐射对ALICE V0检测器的计数器部件的辐射影响。有闪烁器BC404,来自Bicron(Saint-Gobain)的波长转换光纤BCF9929A和光纤BCF98。根据安装在专用设备中的VOC阵列内环的计数器给出的光输出和时间分辨率,根据最高约300 krad的辐射剂量进行测量。在运行ALICE的10年中,可以预计到30%左右的整体光衰减。