We developed a technique for performing quantitative phase reconstructions from differential phase contrast images obtained using a configured detector in a scanning transmission X-ray microscope geometry. The technique uses geometric optics to describe the interaction of the X-ray beam with the specimen, which allows interpretation of the measured intensities in terms of the derivative of the phase thickness. Integration of the resulting directional derivatives is performed using a Fourier integration technique. We demonstrate the approach by reconstructing simulated measurements of a 0.5-μm-diameter gold sphere at 7-keV photon energy.
机译:我们开发了一种技术,用于根据在扫描透射X射线显微镜几何结构中使用配置的检测器获得的差分相位对比图像执行定量相位重建。该技术使用几何光学来描述X射线束与样品的相互作用,从而可以根据相厚的导数来解释所测量的强度。使用傅立叶积分技术对所得的方向导数进行积分。我们通过在直径为7keV的光子能量下重建直径为0.5μm的金球的模拟测量值来演示该方法。