首页> 外文期刊>Nuclear instruments and methods in physics research >Dual Readout: 3d Direct/induced-signals Pixel Systems
【24h】

Dual Readout: 3d Direct/induced-signals Pixel Systems

机译:双读数:3d直接/感应信号像素系统

获取原文
获取原文并翻译 | 示例

摘要

In this paper, 3D-eIectrode pixel detectors are described, in which the bias electrode systems have additional elements. Adding resistors between the bias supply line and each bias electrode together with a signal electrode readout that can measure pulse heights of both polarities could simultaneously provide lower capacitance and improved spatial resolution in both directions. A separate paper ("Dual-readout-strip/pixel systems") covers an alternative-pixels with an added strip readout in one direction which could be used with either planar or 3D-electrodes, and could simultaneously provide a fast trigger and significantly increase the spatial resolution in both directions.
机译:在本文中,描述了3D电极像素检测器,其中偏置电极系统具有其他元素。在偏置电源线和每个偏置电极之间添加电阻器,以及可以测量两个极性的脉冲高度的信号电极读数,可以同时在两个方向上提供较低的电容并提高了空间分辨率。一张单独的纸(“双读数带/像素系统”)覆盖了一个替代像素,并在一个方向上增加了条带读数,可以与平面或3D电极一起使用,并且可以同时提供快速触发并显着增加双向的空间分辨率。