首页> 外文期刊>Nuclear Instruments & Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment >Field flatteners fabricated with a rapid prototyper for K-edge subtraction imaging of small animals
【24h】

Field flatteners fabricated with a rapid prototyper for K-edge subtraction imaging of small animals

机译:用快速原型机制造的场展平机,用于对小动物进行K边缘减影成像

获取原文
获取原文并翻译 | 示例

摘要

One of the difficulties in X-ray imaging is the need to record a wide dynamic range of intensities on the detector. For example, some rays may miss the object being imaged entirely while others may suffer many orders of magnitude attenuation in passing through. In K-edge subtraction (KES) [E. Rubenstein, et al., Trans. Am. Clin. Climatol. Assoc. 97 (1985) 27.] imaging subtle differences in transmission through an object about the absorption edge of an element are used to create an image of the projected density of that element. This is done by a logarithmic subtraction of images acquired with energies above and below the absorption edge. For KES, the detector must register this transmitted intensity range in a linear manner for the subtraction method to be successful. The range of intensities which may strike the detector has inspired the concept of a field flattener. A field flattener is a device placed in the beam path that attenuates the input monochromatic beam to equalize X-ray absorption due to differences in the density of soft and hard tissues of an object before it passes through the object and thus achieves a flattened image. This removes the need for a wide dynamic range linear detector and allows detectors with modest performance to be used successfully in KES applications. The field flattener improves the S/N ratio since X-ray exposures can be increased up to detector saturation. However, a field flattener removes anatomical information from each raw image (above or below K-edge) that may provide useful landmarks. Using rapid prototyping technology, two sets of field flatteners were fabricated and used in a KES experiment. This paper describes the procedure to design and fabricate field flatteners based on animal images from X-ray computed tomography (CT). Analysis of experimental data and KES images of a rat head with and without the field flattener are also presented. The results show a promising improvement of S/N ratio using a field flattener. Problems and improvements are also discussed.
机译:X射线成像的困难之一是需要在检测器上记录强度的宽动态范围。例如,某些光线可能会完全错过要成像的对象,而其他光线可能会在通过时遭受许多数量级的衰减。在K边减法(KES)中[E. Rubenstein等,Trans。上午。临床Climatol。副会长[化学物理学报97(1985)27。]对穿过元件的透射率的细微差异进行成像,以形成该元素的投影密度的图像。这是通过对吸收边缘上方和下方的能量获取的图像进行对数减法来完成的。对于KES,检测器必须以线性方式记录此透射强度范围,以使减法成功。可能撞击检测器的强度范围激发了场展平器的概念。场展平器是一种放置在光束路径中的设备,该设备会衰减输入的单色光束,以均衡X射线的吸收,这是由于物体在穿过物体之前,其软,硬组织的密度差异而导致的,从而获得了平坦的图像。这消除了对宽动态范围线性检测器的需求,并使性能适中的检测器成功用于KES应用中。由于可以将X射线曝光增加到检测器饱和,因此场展平器改善了S / N比。但是,场展平器会从每个原始图像(K边缘上方或下方)移除可能提供有用地标的解剖信息。使用快速原型技术,制造了两组现场展平器,并用于KES实验。本文介绍了基于X射线计算机断层扫描(CT)的动物图像设计和制造场展平器的过程。还介绍了在有和没有场展平器的情况下对大鼠头部的实验数据和KES图像的分析。结果表明,使用场平整器有望改善信噪比。还讨论了问题和改进。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号