A calibration method for telescope photometry, based on the direct illumination of a telescope with a calibrated light source regrouping multiple LEDs, is proposed. Its purpose is to calibrate the instrument response. The main emphasis of the proposed method is the traceability of the calibration process and a continuous monitoring of the instrument in order to maintain a 0.2% accuracy over a period of years. Its specificity is to map finely the response of the telescope and its camera as a function of all light ray parameters. This feature is essential to implement a computer model of the instrument representing the variation of the overall light collection efficiency of each pixel for various filter configurations. We report on hardware developments done for SNDICE, the first application of this direct illumination calibration system which will be installed in Canada France Hawaii telescope (CFHT) for its leading supernova experiment (SNLS).
机译:提出了一种基于望远镜直接照明的校准光度的校准方法,其中校准光源将多个LED重组。其目的是校准仪器响应。所提出方法的主要重点是校准过程的可追溯性和对仪器的连续监控,以在几年内保持0.2%的准确度。它的特殊性是根据所有光线参数精细地绘制望远镜及其照相机的响应。此功能对于实现代表各种滤镜配置的每个像素的整体光收集效率变化的仪器计算机模型至关重要。我们报告了SNDICE的硬件开发情况,SNDICE是这种直接照明校准系统的首次应用,该系统将安装在加拿大,法国,夏威夷望远镜(CFHT)中,以进行领先的超新星实验(SNLS)。