We have studied micro-channel-plate photo-multiplier tubes (MCP-PMT), which realize timing measurements of the single photons with high precision of about 30 ps. We investigated the timing properties of 4 different types with a magnetic field, and measured the lifetime of the gain, quantum efficiency and transit time spread. As an application, we studied the timing resolution of TOF counters by means of Cherenkov-light detection with a MCP-PMT, and attained a 6.2 ps resolution using 3GeV/c pion-beams with readout electronics of 4.1 ps resolution. As another application, we have developed a novel particle identification device, named TOP counter, which is a Cherenkov ring imaging counter with precise timing determination, especially for upgrading B-factory experiments. We performed beam tests with the prototype, and obtained the expected results.%Nagoya University, Furo-cho, Chikusa-ku. Nagoya 464-8601. Japan;
机译:我们研究了微通道板光电倍增管(MCP-PMT),可实现单光子的定时测量,精度约为30 ps。我们用磁场研究了4种不同类型的定时特性,并测量了增益的寿命,量子效率和传输时间扩展。作为一种应用,我们通过使用带有MCP-PMT的Cherenkov光检测技术研究了TOF计数器的定时分辨率,并使用具有4.1 ps分辨率读出电子的3GeV / c离子束,达到了6.2 ps分辨率。作为另一项应用,我们开发了一种名为TOP计数器的新型粒子识别设备,它是具有精确定时确定功能的Cherenkov环形成像计数器,尤其是用于升级B工厂实验的设备。我们用该原型进行了光束测试,并获得了预期的结果。%筑波区筑波町名古屋大学。名古屋464-8601。日本;