首页> 外文期刊>Nuclear instruments and methods in physics research >Energy determination of synchrotron X-ray beam energy in the high energy region of 38-50 keV using powder diffraction patterns of the standard powder Si640b
【24h】

Energy determination of synchrotron X-ray beam energy in the high energy region of 38-50 keV using powder diffraction patterns of the standard powder Si640b

机译:使用标准粉末Si640b的粉末衍射图确定高能区38-50 keV中的同步加速器X射线束能量

获取原文
获取原文并翻译 | 示例

摘要

Powder diffraction patterns from SRM Si640b are used to calibrate the energy scale for two experiments using a monochromated synchrotron X-ray beam in the high energy region 38-50 keV. The energy of the beam is determined to accuracies between 0.0007% and 0.07% of the beam energy. Uncertainties in the energy scale are reduced by correcting for the zero offset angle of the monochromator crystal. Corrections of between -150 and 50 eV are applied to the nominal beam energy. It is shown that systematic errors arising from the misalignment of the monochromator can lead to large systematic shifts in the beam energy.
机译:来自SRM Si640b的粉末衍射图用于在高能区38-50 keV中使用单色同步加速器X射线束校准两次实验的能级。确定束的能量精度为束能量的0.0007%至0.07%。通过校正单色仪晶体的零偏角,可以减少能级的不确定性。 -150至50 eV之间的校正将应用于标称束能量。结果表明,由于单色仪未对准而引起的系统误差会导致光束能量发生较大的系统偏移。