首页> 外文期刊>Nuclear Instruments & Methods in Physics Research >Novel and efficient ~(10)B lined tubelet detector as a replacement for ~3He neutron proportional counters
【24h】

Novel and efficient ~(10)B lined tubelet detector as a replacement for ~3He neutron proportional counters

机译:新颖高效的〜(10)B内衬细管检测器,可替代〜3He中子比例计数器

获取原文
获取原文并翻译 | 示例

摘要

This paper presents a novel and robust proportional detector which addresses the well publicized shortage of ~3He gas by using a ~(10)B lining applied to a tubelet configuration. The advantage of the tubelet structure is that it yields a detector maintaining the form factor of a conventional ~3He tube whilst achieving a sensitivity of up to 75% of a 3 atm ~3He device. The design and fabrication of the tubelet detector is presented and discussed with test data comparing the new detector to existing ~3He and BF_3 tubes. The application of the tubelet design to security and industrial applications including retro-fitting to existing portals and suitability for high integrity oil and gas installations is addressed.
机译:本文提出了一种新颖而强大的比例检测器,该方法通过将〜(10)B衬里应用于微管结构来解决广为人知的〜3He气体短缺问题。细管结构的优势在于,它可以产生一种检测器,该检测器可以保持传统〜3He管的形状因数,同时实现高达3 atm〜3He设备的75%的灵敏度。介绍和讨论了微管检测器的设计和制造,并通过测试数据将新检测器与现有的〜3He和BF_3管进行了比较。解决了将细管设计应用于安全和工业应用的问题,包括对现有门户进行的改造以及对高完整性油气设备的适用性。