In terms of energy resolution, temporal response to burst events, and thermal stability, lanthanum bromide doped with Ce is a much better choice than the traditional Nal(Tl) scintillator for hard X-ray astronomy. We present the test results of a phoswich detector with a diameter of 101.6 mm consisting of 6 mm thick LaBr_3:Ce and 40 mm thick Nal(Tl), which is the largest one of this type reported so far. The measured energy resolution is 10.6% at 60 keV, varying inversely proportional to the square root of the energy, and the energy nonlinearity is found to be less than 1%, as good as those of smaller phoswiches. The coupled scintillators and phototube also show excellent uniformity across the detecting surface, with a deviation of 0.7% on the pulse amplitude produced by 60 keV gamma-rays. Thanks to the large ratio of light decay times of Nal(Tl) and LaBr_3:Ce, 250 ns versus 16 ns, pulse shape discrimination is much easier for this combination than for Nal(Tl)/Csl(Na). As the light decay time of LaBr_3:Ce is about 15 times faster than that of Nal(Tl), this phoswich is more suitable for detection of bright, transient sources such as gamma-ray bursts and soft gamma-ray repeaters. The internal activity of lanthanum produces a count rate of about 6 counts s~(-1) at 37.5 keV in the detector. This peak could be used for in-flight spectral calibration and gain correction.
机译:在能量分辨率,对突发事件的时间响应以及热稳定性方面,对于硬X射线天文学而言,掺有Ce的溴化镧是比传统的Nal(Tl)闪烁体更好的选择。我们介绍了直径为101.6毫米,由6毫米厚的LaBr_3:Ce和40毫米厚的Nal(Tl)组成的荧光检测器的测试结果,这是迄今为止报道的最大的这种类型。在60 keV时,测得的能量分辨率为10.6%,与能量的平方根成反比,并且发现能量非线性小于1%,与较小的荧光灯相同。耦合的闪烁体和光电管在整个检测表面上也表现出出色的均匀性,在60 keV伽马射线产生的脉冲幅度上偏差为0.7%。由于Nal(Tl)和LaBr_3:Ce的光衰减时间比例大,分别为250 ns和16 ns,因此与Nal(Tl)/ Csl(Na)相比,此组合的脉冲形状判别要容易得多。由于LaBr_3:Ce的光衰减时间比Nal(Tl)的光衰减时间快15倍,因此这种荧光灯更适合检测明亮的瞬态光源,例如伽马射线暴和软伽马射线中继器。镧的内部活性在检测器中以37.5 keV产生约6个计数s〜(-1)的计数率。该峰可用于飞行中的光谱校准和增益校正。

著录项

  • 来源
    《Nuclear Instruments & Methods in Physics Research》 |2012年第2012期|p.24-28|共5页
  • 作者单位

    Department of Engineering Physics and Center for Astrophysics, Tsinghua University, Beijing 100084, China,Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education, China;

    Department of Engineering Physics and Center for Astrophysics, Tsinghua University, Beijing 100084, China,Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education, China;

    Department of Engineering Physics and Center for Astrophysics, Tsinghua University, Beijing 100084, China,Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education, China;

    Department of Engineering Physics and Center for Astrophysics, Tsinghua University, Beijing 100084, China,Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education, China;

    Department of Engineering Physics and Center for Astrophysics, Tsinghua University, Beijing 100084, China,Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education, China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    LaBr_3; Nal; phoswich; X-ray; gamma-ray; astronomy; burst;

    机译:LaBr_3;纳尔phoswich;X射线伽马射线;天文学;爆;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号