首页> 外文期刊>Nuclear Instruments & Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment >Measurement of fast neutron spectrum using CR-39 detectors and a new image analysis program (autoTRAK_n)
【24h】

Measurement of fast neutron spectrum using CR-39 detectors and a new image analysis program (autoTRAK_n)

机译:使用CR-39探测器和新的图像分析程序(autoTRAK_n)测量快速中子光谱

获取原文
获取原文并翻译 | 示例

摘要

An attempt is made to estimate the neutron spectrum using the CR-39 (Solid state nuclear track) detector and a new image analyzing program. For this purpose the earlier developed program (autoTRAK) is modified by introducing the required features such as angular correction for the recoil particles, fluence-to-dose conversion coefficient, detection sensitivity of CR-39 detectors, etc. to make it applicable for neutron spectrometry and dosimetry. This upgraded program (autoTRAK_n) is tested with a mono-energetic source (D-T) and two other standard neutron sources, viz. ~(241)Am-Be and ~(252)Cf. The program is validated by reproducing these standard spectra, and comparing with the spectra reported by other investigators using different measuring techniques. The ratios of dose equivalent (H~*(10)) to fluence (Φ) are also estimated from the spectra and are compared with the reference values for these neutron sources. An additional feature of this program is explored for counting high density overlapping tracks more precisely and effectively compared to other commonly used image analyzing softwares. This method is found to be simple and promising, which can always be used as a supplementary measuring technique. The details of the modified program, reproduction and comparison of the neutron spectra, reproducibility of the methodology and example of overlapping track counting are presented and discussed.
机译:尝试使用CR-39(固态核径迹)探测器和新的图像分析程序来估计中子谱。为此,通过引入所需的功能(例如反冲粒子的角度校正,注量剂量转换系数,CR-39探测器的探测灵敏度等)来修改较早开发的程序(autoTRAK),使其适用于中子光谱学和剂量学。此升级程序(autoTRAK_n)已通过单能源(D-T)和其他两个标准中子源进行测试。 〜(241)Am-Be和〜(252)Cf。通过复制这些标准光谱,并与其他研究人员使用不同的测量技术报告的光谱进行比较,可以验证该程序的有效性。剂量当量(H〜*(10))与能量密度(Φ)的比率也可以从光谱中估算出来,并与这些中子源的参考值进行比较。与其他常用的图​​像分析软件相比,该程序的另一个功能是可以更精确,更有效地计数高密度重叠轨道。发现该方法简单且有希望,可以始终用作辅助测量技术。介绍并讨论了修改程序的细节,中子谱的再现和比较,方法的可重复性以及重叠轨道计数的示例。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号