首页> 外文期刊>Nuclear Instruments & Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment >Thermal performance analysis and measurements of the prototype cryomodules of European XFEL accelerator-Part Ⅱ
【24h】

Thermal performance analysis and measurements of the prototype cryomodules of European XFEL accelerator-Part Ⅱ

机译:欧洲XFEL加速器原型低温模块的热性能分析和测量(第二部分)

获取原文
获取原文并翻译 | 示例

摘要

Three accelerator prototype cryomodules (CMs) for the European XFEL have been produced, assembled and tested at DESY in a wide international collaboration. The heat load budget is a key element in the qualification of these CMs. We describe in this paper the measurements performed in the Cryomodule test bench (CMTB) to evaluate the thermal performances of the three prototype CMs. We present at first the methodology and instrumentation used for the measurements, then we analyse the main contributions to the heat loads at various temperature levels and finally we compare the measured values with the ones calculated and reported in the first part of this paper.
机译:在广泛的国际合作中,已在DESY生产,组装和测试了三个用于欧洲XFEL的加速器原型低温模块(CM)。热负荷预算是这些CM资格的关键因素。我们在本文中描述了在低温模块测试台(CMTB)中执行的测量,以评估三个原型CM的热性能。我们首先介绍用于测量的方法和仪器,然后分析在不同温度水平下对热负荷的主要贡献,最后将测量值与本文第一部分中计算和报告的值进行比较。