Design and development of a high resolution animal SPECT scanner dedicated for rat and mouse imaging

机译:专门用于大鼠和小鼠成像的高分辨率动物SPECT扫描仪的设计和开发

获取原文
获取原文并翻译 | 示例

摘要

A dedicated small-animal SPECT system, HiReSPECT, was designed and developed to provide a high resolution molecular imaging modality in response to growing research demands. HiReSPECT is a dual-head system mounted on a rotating gantry. The detection system is based on pixelated CsI(Na) scintillator crystals coupled to two Hamamatsu H8500 Position Sensitive Photomultiplier Tubes in each head. Also, a high resolution parallel-hole collimator is applied to every head. The dimensions of each head are 50 mm × 100 mm, enabling sufficient transaxial and axial fields-of-view (TFOV and AFOV), respectively, for coverage of the entire mouse in single-bed position imaging. However, a 50 mm TFOV is not sufficient for transaxial coverage of rats. To address this, each head can be rotated by 90 degrees in order to align the larger dimension of the heads with the short body axis, allowing tomographic data acquisition for rats. An innovative non-linear recursive filter was used for signal processing/detection. Resolution recovery was also embedded in the modified Maximum-Likelihood Expectation Maximization (MLEM) image reconstruction code to compensate for Collimator-Detector Response (CDR). Moreover, an innovative interpolation algorithm was developed to speed up the reconstruction code. The planar spatial resolution at the head surface and the image spatial resolutions were 1.7 mm and 1.2-1.6 mm, respectively. The measurements followed by post-processing showed that the observed count rate at 20% count loss is about 42 kcps. The system sensitivity at the collimator surface for heads 1 and 2 were 1.32 cps/μCi and 1.25 cps/μCi, respectively. The corresponding values were 1.18 cps/μCi and 1.02 cps/μCi at 8 cm distance from the collimator surfaces. In addition, whole-body scans of mice demonstrated appropriate imaging capability of the HiReSPECT.
机译:设计和开发了专用的小动物SPECT系统HiReSPECT,以响应不断增长的研究需求提供高分辨率的分子成像模式。 HiReSPECT是安装在旋转机架上的双头系统。该检测系统基于像素化的CsI(Na)闪烁体晶体,该晶体与每个头中的两个Hamamatsu H8500位置敏感光电倍增管相连。而且,高分辨率平行孔准直仪被应用于每个头。每个头的尺寸为50 mm×100 mm,分别具有足够的跨轴和轴向视场(TFOV和AFOV),以覆盖单床位置成像中的整个鼠标。但是,50毫米TFOV不足以对大鼠进行跨轴覆盖。为了解决这个问题,每个头都可以旋转90度,以使头的较大尺寸与短身体轴对齐,从而可以获取大鼠的断层扫描数据。创新的非线性递归滤波器用于信号处理/检测。分辨率恢复也嵌入在修改后的最大似然期望最大化(MLEM)图像重建代码中,以补偿准直检测器响应(CDR)。此外,开发了创新的插值算法以加快重构代码的速度。头部表面的平面空间分辨率和图像空间分辨率分别为1.7 mm和1.2-1.6 mm。经过后处理的测量结果表明,在计数损失为20%时观察到的计数率约为42 kcps。头1和头2在准直仪表面的系统灵敏度分别为1.32 cps /μCi和1.25 cps /μCi。距准直仪表面8 cm处的相应值为1.18 cps /μCi和1.02 cps /μCi。另外,对小鼠的全身扫描证明了HiReSPECT具有适当的成像能力。

著录项

  • 来源
  • 作者单位

    Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran;

    Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran;

    Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran,Parto Negar Persia Co, Tehran, Iran;

    Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran,Parto Negar Persia Co, Tehran, Iran;

    Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran,Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran;

    Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran;

    Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran,Parto Negar Persia Co, Tehran, Iran;

    Chronic Respiratory Disease Research Center, NRITLD, Masih Daneshvari Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran,PET/CT and Cyclotron Center, Masih Daneshvari Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran;

    Department of Radiology, Johns Hopkins University, Baltimore, MD, USA,Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD, USA;

    Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran,Tehran University of Medical Sciences, Department of Medical Physics and Biomedical Engineering, Pousina St, Tehran, Iran;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    SPECT; Small animal imaging; Instrumentation; HiReSPECT;

    机译:SPECT;小动物成像;仪器仪表;HiReSPECT;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号