Beta particles sensitivity of an all-carbon detector

机译:全碳探测器的Beta颗粒灵敏度

获取原文
获取原文并翻译 | 示例

摘要

The response of high quality polycrystalline diamond pixel detectors to ~(90)Sr beta particles is reported. Laser induced surface graphitization was used to realize 36 conductive contacts with 1 mm × 1 mm area each, pitch 1.2 mm, on one detector side whereas a 8 mm × 8 mm large area graphite contact was realized on the other face for grounding or biasing. A proximity board was used to hold the matrix, the amplifiers and to bond nine pixels to test homogeneity of response among 36 detector pixels. Two configurations were used to test charge collection uniformity and signal dependence on voltage. Both configurations showed noise pedestal fitted with a Gaussian curve of 1150 equivalent electrons (1σ) and typical beta source particles spectrum. Reversing the bias polarity the pulse height distribution does not change and the saturation of most probable value of charge collection was observed around ± 200 V (0.4 V/μm) with reasonable pixel response uniformity equal to a most probable value 1.28 ± 0.05 fC. The charge collection efficiency (CCE) measurement was implemented using coincidence mode acquisition with an external trigger made by a commercial polycrystalline diamond slab. The detector shows a CCE = 0.59 estimated using the 1 mm~2 large graphite pixel. The information earned with this first prototype will be used to design the new board with amplifying electronics for reading all 36 pixels at a time and perform experiments with monochromatic high energy electrons.
机译:报告了高质量的多晶金刚石像素探测器对〜(90)Srβ粒子的响应。激光诱导的表面石墨化用于在一个检测器一侧实现36个导电触点,每个触点的面积为1 mm×1 mm,间距为1.2 mm,而在另一面上实现了8 mm×8 mm的大面积石墨触点以接地或偏置。一块接近板用来固定矩阵,放大器并粘合九个像素,以测试36个检测器像素之间的响应均匀性。使用两种配置来测试电荷收集的均匀性和信号对电压的依赖性。两种配置都显示了噪声基座,该基座具有1150个等效电子(1σ)的高斯曲线和典型的β源粒子光谱。反转偏置极性,脉冲高度分布不会改变,并且在±200 V(0.4 V /μm)左右观察到最可能的电荷收集值饱和,并且像素响应均匀性等于最可能值1.28±0.05 fC。电荷收集效率(CCE)的测量是通过使用巧合模式采集和由商用多晶金刚石板制成的外部触发器来实现的。检测器显示使用1 mm〜2大石墨像素估算的CCE = 0.59。从第一个原型获得的信息将用于设计带有放大电子设备的新板,以一次读取所有36个像素,并使用单色高能电子进行实验。

著录项

  • 来源
  • 作者单位

    Department of Sciences, University Roma Tre, Via Vasca Navale, 84, 00146 Rome, Italy;

    INFN - Roma Tre, Via Vasca Navale, 84, 00146 Rome, Italy,Institute of Photonics and Nanotechnology, CNR, Via Cineto Romano, 42, 00156 Rome, Italy;

    Department of Sciences, University Roma Tre, Via Vasca Navale, 84, 00146 Rome, Italy,INFN - Roma Tre, Via Vasca Navale, 84, 00146 Rome, Italy,Institute of Photonics and Nanotechnology, CNR, Via Cineto Romano, 42, 00156 Rome, Italy;

    INFN - Roma Tre, Via Vasca Navale, 84, 00146 Rome, Italy,INFN-LNF, Via Enrico Fermi, 40, 00040 Frascati, Italy;

    A.M. Proklhorov General Physics Institute, RAS, 38 Vavilova Str., 119991 Moscow, Russia;

    A.M. Proklhorov General Physics Institute, RAS, 38 Vavilova Str., 119991 Moscow, Russia;

    A.M. Proklhorov General Physics Institute, RAS, 38 Vavilova Str., 119991 Moscow, Russia;

    A.M. Proklhorov General Physics Institute, RAS, 38 Vavilova Str., 119991 Moscow, Russia;

    A.M. Proklhorov General Physics Institute, RAS, 38 Vavilova Str., 119991 Moscow, Russia;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Polycrystalline diamond; Graphite contacts; 2D arrays; CCE; Beta particles detectors;