One possibility to make a fast and radiation resistant shower maximum detector is to use a secondary emitter as an active element. We report our studies of microchannel plate photomultipliers (MCPs) as the active element of a shower-maximum detector. We present test beam results obtained using Photonis XP85011 to detect secondary particles of an electromagnetic shower. We focus on the use of the multiple pixels on the Photonis MCP in order to find a transverse two-dimensional shower distribution. A spatial resolution of 0.8 mm was obtained with an 8 GeV electron beam. A method for measuring the arrival time resolution for electromagnetic showers is presented, and we show that time resolution better than 40 ps can be achieved.
机译:制造快速且抗辐射的淋浴器最大值探测器的一种可能性是使用辅助发射器作为有源元件。我们报告了我们的研究微通道板光电倍增管(MCP)作为淋浴最大探测器的活动元素。我们介绍使用Photonis XP85011检测电磁淋浴器的二次粒子获得的测试光束结果。我们专注于在Photonis MCP上使用多个像素,以便找到横向二维淋浴器分布。用8 GeV电子束获得的空间分辨率为0.8 mm。提出了一种测量电磁淋浴的到达时间分辨率的方法,我们证明了可以实现优于40 ps的时间分辨率。