Coulomb field strength measurement by electro-optic spectral decoding system at the CALIFES beam line

机译:电光光谱解码系统在CALIFES光束线上测量库仑场强

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Electro-optic (EO) techniques are increasingly used for longitudinal bunch profile measurements. A bunch profile monitor, based on electro-optic spectral decoding (EOSD), has been developed and demonstrated on the CALIFES beam line at CERN. The EO response is analysed using a frequency domain description, and two methods for extraction of absolute Coulomb field strengths from the electron bunch are demonstrated. Measurements at field strengths up to 1.3 MV/m agree with the expectation based on independent charge measurements.
机译:电光(EO)技术越来越多地用于纵向束轮廓测量。基于电光频谱解码(EOSD)的束轮廓监测仪已经开发出来,并在CERN的CALIFES光束线上进行了演示。使用频域描述分析EO响应,并演示了两种从电子束中提取绝对库仑场强的方法。在最高1.3 MV / m的场强下进行的测量符合基于独立电荷测量的预期。