Since the timing resolution was significantly improved using silicon photomultipliers (Si-PMs) combined with fast scintillators, we expect that phoswich detectors will be used in future TOF-PET systems. However, no practical phoswich detector has been proposed for TOF-PET detectors. We conducted timing performance measurements of phoswich detectors comprised of two types of Ce-doped LGSO scintillators with different decay times coupled to Si-PMs and digitized the output signals using a high bandwidth digital oscilloscope. We prepared three types of LGSOs (LGSO-fast, LGSO-standard, and LGSO-slow) with different Ce concentrations. After measuring the decay time, the energy performance, and the timing performance of each LGSO, we conducted pulse shape analysis and timing resolution measurements for two versions of phoswich LGSOs: LGSO-standard/LGSO-fast and LGSO-slow/LGSO-fast combinations. The pulse shape spectra for a 10-mm-long crystal LGSO-slow/LGSO-fast combination showed good separation of the front and back crystals with a peak-to-valley ratio of 2.0. The timing resolutions for the 20-mm-long crystal LGSO-slow/LGSO-fast combination were ~300 ps FWHM. The timing resolutions for the phoswich LGSOs were slightly inferior than that measured with the individual LGSO fast, but the acquired timing resolution for the phoswich configuration, ~300 ps with a LGSO-slow/LGSO-fast combination, is adequate for TOF-PET systems. We conclude that LGSO phoswich detectors are promising for TOF-DOI-PET systems.
机译:由于结合使用硅光电倍增器(Si-PM)和快速闪烁器可以显着提高时序分辨率,因此我们希望在未来的TOF-PET系统中使用磷光检测器。然而,尚未提出用于TOF-PET检测器的实用的荧光检测器。我们对由两种类型的Ce掺杂的LGSO闪烁体组成的荧光检测器进行了定时性能测量,这些衰变时间与Si-PM耦合在一起,并使用高带宽数字示波器将其数字化。我们准备了三种具有不同Ce浓度的LGSO(LGSO快,LGSO标准和LGSO慢)。在测量每个LGSO的衰减时间,能量性能和定时性能之后,我们对两种版本的磷光LGSO进行了脉冲形状分析和定时分辨率测量:LGSO标准/ LGSO-fast和LGSO-low / LGSO-fast组合。 10毫米长的LGSO慢/ LGSO快晶体的脉冲形状光谱显示,前,后晶体的分离度很好,峰谷比为2.0。 LGSO慢/ LGSO快的20 mm长晶体的时序分辨率为〜300 ps FWHM。磷光LGSO的时序分辨率比单个LGSO快速测量的时序分辨率稍差,但是磷光配置的获得的时序分辨率约为300 ps(LGSO慢/ LGSO快速组合),适用于TOF-PET系统。我们得出的结论是,LGSO荧光检测器有望用于TOF-DOI-PET系统。

著录项

  • 来源
  • 作者单位

    Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, Nagoya, Japan;

    Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, Nagoya, Japan,Department of Radiology, Daiyukai General Hospital, Ichinomiya, Japan;

    Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, Nagoya, Japan;

    Department of Biomedical Engineering, Korea University, Seoul, South Korea;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    TOF; DOI; Phoswich; LGSO;

    机译:到F;二;磷三明治LGSO;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号