首页> 外文期刊>Nuclear Instruments & Methods in Physics Research >Predicted performance of a PG-SPECT system using CZT primary detectors and secondary Compton-suppression anti-coincidence detectors under near-clinical settings for boron neutron capture therapy
【24h】

Predicted performance of a PG-SPECT system using CZT primary detectors and secondary Compton-suppression anti-coincidence detectors under near-clinical settings for boron neutron capture therapy

机译:使用CZT主探测器和辅助Compton抑制反符合探测器在接近临床环境下进行硼中子俘获治疗的PG-SPECT系统的预测性能

获取原文
获取原文并翻译 | 示例
           

摘要

A test version of a prompt-gamma single photon emission computed tomography (PG-SPECT) system for boron neutron capture therapy (BNCT) using a CdZnTe (CZT) semiconductor detector with a secondary BGO anti-Compton suppression detector has been designed. A phantom with healthy tissue region of pure water, and 2 tumor regions of 5 wt% borated polyethylene was irradiated to a fluence of 1.3×10~9n/cm~2. The number of 478 keV foreground, background, and net counts were measured for each detector position and angle. Using only experimentally measured net counts, an image of the 478 keV production from the ~(10)B(n,α)~7Li~* reaction was reconstructed. Using Monte Carlo simulation and the experimentally measured background counts, the reliability of the system under clinically accurate parameters was extrapolated. After extrapolation, it was found that the value of the maximum-value pixel in the reconstructed 478 keV γ-ray production image overestimates the simulated production by an average of 9.2%, and that the standard deviation associated with the same value is 11.4%.
机译:设计了使用CdZnTe(CZT)半导体探测器和辅助BGO抗康普顿抑制探测器的硼中子俘获疗法(BNCT)的快速伽马单光子发射计算机断层扫描(PG-SPECT)系统的测试版。用纯净水的健康组织区域和2个5 wt%硼酸化聚乙烯的肿瘤区域照射模型,使其通量为1.3×10〜9n / cm〜2。对于每个探测器位置和角度,测量了478 keV的前景,背景和净计数。仅使用实验测得的净计数,即可重建〜(10)B(n,α)〜7Li〜*反应生成478 keV的图像。使用蒙特卡洛模拟和实验测量的背景计数,可以推断出该系统在临床准确参数下的可靠性。外推后发现,在重建的478 keVγ射线产生图像中,最大值像素的值高估了模拟产生的9.2%的平均值,与该值相关的标准偏差为11.4%。

著录项

  • 来源
  • 作者单位

    Laboratory for Advanced Nuclear Energy, Tokyo Institute of Technology, 2-12-N1-16 Ookayama, Meguro-ku, Tokyo, 152-8550, Japan;

    Laboratory for Advanced Nuclear Energy, Tokyo Institute of Technology, 2-12-N1-16 Ookayama, Meguro-ku, Tokyo, 152-8550, Japan;

    Laboratory for Advanced Nuclear Energy, Tokyo Institute of Technology, 2-12-N1-16 Ookayama, Meguro-ku, Tokyo, 152-8550, Japan;

    Laboratory for Advanced Nuclear Energy, Tokyo Institute of Technology, 2-12-N1-16 Ookayama, Meguro-ku, Tokyo, 152-8550, Japan;

    Laboratory for Advanced Nuclear Energy, Tokyo Institute of Technology, 2-12-N1-16 Ookayama, Meguro-ku, Tokyo, 152-8550, Japan;

    Kyoto University Research Reactor Institute, Kumatori-cho, Sennan-gun, Osaka, 590-0494, Japan;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Boron neutron capture therapy; CZT detector; BGO detector; PG-SPECT;