首页> 外文期刊>Nuclear Instruments & Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment >Model independent approach to the single photoelectron calibration of photomultiplier tubes
【24h】

Model independent approach to the single photoelectron calibration of photomultiplier tubes

机译:独立于模型的方法对光电倍增管进行单光电子校准

获取原文
获取原文并翻译 | 示例
           

摘要

The accurate calibration of photomultiplier tubes is critical in a wide variety of applications for which it is necessary to know the absolute number of detected photons or precisely determine the resolution of the signal. Conventional calibration methods rely on fitting the photomultiplier response to a low intensity light source with analytical approximations to the single photoelectron distribution. We show that this approach often leads to biased estimates due to an inability to model the full distribution accurately, especially at low charge values. We present a simple statistical method to extract the relevant single photoelectron calibration parameters (first two central moments) without making any assumptions about the underlying single photoelectron distribution. We illustrate the use of this method through the calibration of a Hamamatsu R11410 photomultiplier tube and study the accuracy and precision of the method using Monte Carlo simulations. The method is found to have significantly reduced bias compared to conventional methods and works under a wide range of light intensities, making it suitable for the simultaneous calibration of large arrays of photomultiplier tubes where uniform illumination may not be possible.
机译:光电倍增管的精确校准在各种各样的应用中至关重要,对于这些应用,必须知道检测到的光子的绝对数量或精确确定信号的分辨率。常规的校准方法依赖于光电倍增管对低强度光源的响应,以及对单个光电子分布的解析近似。我们表明,由于无法准确地对整个分布进行建模,尤其是在低电量时,这种方法通常会导致估计偏差。我们提出一种简单的统计方法来提取相关的单光电子校准参数(前两个中心矩),而无需对基础单光电子分布进行任何假设。我们通过对Hamamatsu R11410光电倍增管进行校准来说明该方法的使用,并使用蒙特卡洛模拟研究该方法的准确性和精度。与常规方法相比,该方法的偏置已大大降低,并且可在较宽的光强度范围内工作,从而使其适用于无法均匀照明的大型光电倍增管阵列的同时校准。

著录项

  • 来源
  • 作者单位

    Kavli Institute for Cosmological Physics, University of Chicago, Chicago, IL 60637, USA,Enrico Fermi Institute, University of Chicago, Chicago, IL 60637, USA,Department of Physics, University of Chicago, Chicago, IL 60637, USA;

    Kavli Institute for Cosmological Physics, University of Chicago, Chicago, IL 60637, USA,Enrico Fermi Institute, University of Chicago, Chicago, IL 60637, USA,Department of Physics, University of Chicago, Chicago, IL 60637, USA;

    Fermi National Accelerator Laboratory, Batavia, IL 60510, USA,Kavli Institute for Cosmological Physics, University of Chicago, Chicago, IL 60637, USA;

    Kavli Institute for Cosmological Physics, University of Chicago, Chicago, IL 60637, USA,Department of Physics, University of Chicago, Chicago, IL 60637, USA;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Photomultiplier tubes; Single photoelectron response; Calibration;

    机译:光电倍增管;单光电子响应;校准;