首页> 外文期刊>Nuclear Instruments & Methods in Physics Research >A fully automated and scalable timing probe-based method for time alignment of the LabPET Ⅱ scanners
【24h】

A fully automated and scalable timing probe-based method for time alignment of the LabPET Ⅱ scanners

机译:基于全自动,可扩展的定时探针的LabPETⅡ扫描仪时间对准方法

获取原文
获取原文并翻译 | 示例
           

摘要

A fully automated time alignment method based on a positron timing probe was developed to correct the channel-to-channel coincidence time dispersion of the LabPET II avalanche photodiode-based positron emission tomography (PET) scanners. The timing probe was designed to directly detect positrons and generate an absolute time reference. The probe-to-channel coincidences are recorded and processed using firmware embedded in the scanner hardware to compute the time differences between detector channels. The time corrections are then applied in real-time to each event in every channel during PET data acquisition to align all coincidence time spectra, thus enhancing the scanner time resolution. When applied to the mouse version of the LabPET II scanner, the calibration of 6 144 channels was performed in less than 15 min and showed a 47% improvement on the overall time resolution of the scanner, decreasing from 7 ns to 3.7 ns full width at half maximum (FWHM).
机译:开发了一种基于正电子定时探针的全自动时间对准方法,以校正LabPET II基于雪崩光电二极管的正电子发射断层扫描(PET)扫描仪的通道间重合时间色散。定时探头设计用于直接检测正电子并生成绝对时间基准。使用嵌入在扫描仪硬件中的固件来记录和处理探头与通道的重合,以计算检测器通道之间的时间差。然后将时间校正实时应用于PET数据采集期间每个通道中的每个事件,以对齐所有重合时间谱,从而提高扫描仪的时间分辨率。当应用于LabPET II扫描仪的鼠标版本时,在不到15分钟的时间内执行了6144个通道的校准,显示扫描仪的整体时间分辨率提高了47%,从7ns降至3.7ns的全宽最大值的一半(FWHM)。

著录项

  • 来源
  • 作者单位

    Department of Electrical and Computer Engineering, Institut interdisciplinaire d’innovation technologique, Université de Sherbrooke;

    Sherbrooke Molecular Imaging Center and Department of Nuclear Medicine and Radiobiology, Université de Sherbrooke;

    Department of Electrical and Computer Engineering, Institut interdisciplinaire d’innovation technologique, Université de Sherbrooke;

    Sherbrooke Molecular Imaging Center and Department of Nuclear Medicine and Radiobiology, Université de Sherbrooke;

    Department of Electrical and Computer Engineering, Institut interdisciplinaire d’innovation technologique, Université de Sherbrooke;

    Sherbrooke Molecular Imaging Center and Department of Nuclear Medicine and Radiobiology, Université de Sherbrooke;

    Department of Electrical and Computer Engineering, Institut interdisciplinaire d’innovation technologique, Université de Sherbrooke;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Positron emission tomography (PET); Timing probe; Time alignment;