【24h】

Spectrometric performance of a HPGe semi-planar detector with large diameter

机译:具有大直径的HPGE半平面检测器的光谱性能

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

We present the results of the development of the technology for the growth of HPGe ingots with a diameter of 110-120 mm and the characteristics of the first detector made of a crystal of this diameter. A semi-planar detector with a crystal size of 110x35 mm provided an energy resolution of 570 eV Con 60 keV), 702 eV (on 122 keV), 1337 eV (on 662 keV) and 1830 eV (on 1332 keV) with noise level on pulser peak of 556 eV. The relative detection efficiency of gamma radiation of the detector on the energy of 1332 keV was 65%.
机译:我们介绍了直径为110-120mm的HPGE锭的生长的技术发展结果,以及由该直径的晶体制成的第一检测器的特性。半平面探测器,晶体尺寸为110x35 mm,提供了570 eV CON 60 kev的能量分辨率,702eV(在122keV),1337eV(662keV)和1830 eV(1332keV上),具有噪音水平关于556eV的脉冲峰。 γ辐射对1332keV的能量的γ辐射的相对检测效率为65%。