In this paper the closed orbit correction of the Heavy Ion Medical Machine (HIMM) synchrotron is described. Results of simulations and measurements are presented. Consistently with simulations, it is possible to correct the maximum closed orbit distortion of the HIMM synchrotron down to 2.4mm in the horizontal direction and 0.7mm in the vertical one. The errors of dipole magnets, especially the longitudinal alignment errors (Δs), have large impact on the horizontal correction results. A Singular Value Decomposition (SVD) algorithm is adopted for computing the correction. The residual orbits and the effects of reducing the number of singular values are analytically expressed and simulated. In addition, the influences of BPM reading errors as well as corrector setting errors are analyzed. For further optimization, the method to estimate the dipole errors is studied. In the commissioning, the maximum closed orbits at BPMs can also be well corrected to within lmm through SVD algorithm.
机译:在本文中,描述了重离子医用机(HIMM)同步rotron的闭合轨道校正。提出了模拟结果和测量结果。始终如一的仿真,可以将HIMM同步的最大闭合轨道失真校正到水平方向上的最大闭合轨道畸变为2.4mm,垂直于垂直方向0.7mm。偶极磁体的误差,尤其是纵向对准误差(Δs)对水平校正结果具有很大影响。采用奇异值分解(SVD)算法来计算校正。分析和模拟减少奇异值数量的残余轨道和效果。此外,分析了BPM读取误差以及校正器设置误差的影响。为了进一步优化,研究了估计偶极误差的方法。在调试中,BPMS的最大闭合轨道也可以通过SVD算法在LMM内进行很好地校正。

著录项

  • 来源
  • 作者单位

    Institute of Modern Physics Chinese Academy of Sciences Lanzhou 730000 China University of Chinese Academy of Sciences Beijing 100049 China;

    Institute of Modern Physics Chinese Academy of Sciences Lanzhou 730000 China;

    Institute of Modern Physics Chinese Academy of Sciences Lanzhou 730000 China;

    Institute of Modern Physics Chinese Academy of Sciences Lanzhou 730000 China;

    Institute of Modern Physics Chinese Academy of Sciences Lanzhou 730000 China University of Chinese Academy of Sciences Beijing 100049 China;

    Institute of Modern Physics Chinese Academy of Sciences Lanzhou 730000 China;

    Institute of Modern Physics Chinese Academy of Sciences Lanzhou 730000 China University of Chinese Academy of Sciences Beijing 100049 China;

    Institute of Modern Physics Chinese Academy of Sciences Lanzhou 730000 China University of Chinese Academy of Sciences Beijing 100049 China;

    Institute of Modern Physics Chinese Academy of Sciences Lanzhou 730000 China University of Chinese Academy of Sciences Beijing 100049 China;

    Institute of Modern Physics Chinese Academy of Sciences Lanzhou 730000 China University of Chinese Academy of Sciences Beijing 100049 China;

    Institute of Modern Physics Chinese Academy of Sciences Lanzhou 730000 China University of Chinese Academy of Sciences Beijing 100049 China;

    Institute of Modern Physics Chinese Academy of Sciences Lanzhou 730000 China University of Chinese Academy of Sciences Beijing 100049 China;

    Institute of Modern Physics Chinese Academy of Sciences Lanzhou 730000 China University of Chinese Academy of Sciences Beijing 100049 China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Closed orbit distortion; Closed orbit correction; SVD; Synchrotron;