首页> 外文期刊>Nuclear Instruments & Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment >Experimental test and characterization of BASIC64, a new mixed-signal front-end ASIC for SiPM detectors
【24h】

Experimental test and characterization of BASIC64, a new mixed-signal front-end ASIC for SiPM detectors

机译:Basic64的实验测试和表征,一种用于SIPM探测器的新的混合信号前端ASIC

获取原文
获取原文并翻译 | 示例

摘要

BASIC64 is a new multichannel front-end ASIC for Silicon photomultiplier detectors used in PET systems. The preamplifier input resistance is similar to 50 Omega, low enough not to further affect the slope of incoming current pulses, already plagued by the presence of stray series inductance. For each channel, the signals generated by the detector follow two parallel processing paths, respectively for timing and energy measurements. The results of experimental test and characterization for timing accuracy and gain linearity are presented and confirm that BASIC64 is suitable for PET applications.
机译:Basic64是PET系统中使用的硅光电倍增器探测器的新型多声道前端ASIC。前置放大器输入电阻类似于50Ω,足够低,不能进一步影响输入电流脉冲的斜率,已经通过杂散串联电感的存在困扰。对于每个通道,通过检测器生成的信号分别遵循两个并行处理路径以进行定时和能量测量。提出了实验测试和表征时刻精度和增益线性的结果,并确认Basic64适用于PET应用。