Radiation damage effect on time resolution of 6 series-connected SiPMs for MEG Ⅱ positron timing counter

机译:辐射损伤对MEGⅡ正电子正式计数器6系列连接SIPMS的时间分辨率

获取原文
获取原文并翻译 | 示例

摘要

We studied the impact of radiation damage on scintillation counters read out by six SiPMs connected in series focusing on their time resolution. Six SiPMs from AdvanSiD were irradiated step by step with a 37 MBq Sr-90 source. At the integrated dose expected at the end of the MEG II experiment, the time resolution at 30 degrees C was measured to be worse by similar to 29%. However, the deterioration is found to be reduced to similar to 6% at 10 degrees C since thermal dark noise is suppressed. We also tested the effect of connecting in series differently damaged SiPMs. We observed a position dependence of the time center in a counter, which worsened the time resolution.
机译:我们研究了辐射损伤对速度计数器读取的闪烁计数器的影响,六个综合调传在其时间分辨率上的六种纱布。通过37 MBQ SR-90来源逐步辐照来自Advansid的六种Sipms。在PEG II实验结束时预期的集成剂量,测量30摄氏度的时间分辨率与29%相似。然而,发现劣化将其降低至同样于10摄氏度的6%,因为抑制了热暗噪声。我们还测试了连接串联不同损坏的SIPMS的效果。我们观察到时钟在计数器中的位置依赖,这使得时间分辨率恶化。