首页> 外文期刊>Nuclear Instruments & Methods in Physics Research >Reduction of waveguide vacuum trips in CEBAF accelerating cavities with a combination ion pump and non-evaporable getter pump
【24h】

Reduction of waveguide vacuum trips in CEBAF accelerating cavities with a combination ion pump and non-evaporable getter pump

机译:结合离子泵和非蒸发吸气剂泵,减少CEBAF加速腔中的波导真空跳闸

获取原文
获取原文并翻译 | 示例

摘要

Pressure spikes in the fundamental power coupler waveguide are a significant source of trips during the operation of both original and refurbished superconducting radio-frequency cavities installed in the CEBAF accelerator. In its original configuration, two waveguides from a cavity-pair are connected to a single 32 1/s ion pump. In 2017 a new cavity-pair was installed in a refurbished cryomodule in which a NEXTorr~® D200-5 combination ion pump and non-evaporable getter pump was installed for each waveguide. It is shown that hydrogen is the dominant residual gas in the waveguide and simulations with Molflow+ indicated that the new pumping scheme allows reducing the pressure at the end of the waveguide by a factor of ~ 5, compared to the original configuration. The new cavity-pair has been operating in CEBAF for a total of 431 days and it only had a total of 3 trips due to vacuum spikes in the waveguide.
机译:在CEBAF加速器中安装的原始和翻新的超导射频腔中,基本功率耦合器波导中的压力尖峰是跳闸的重要来源。在其原始配置中,一对腔对中的两个波导连接到单个32 1 / s离子泵。 2017年,在翻新的低温模块中安装了新的腔对,其中为每个波导安装了NEXTorr〜®D200-5组合离子泵和不可蒸发吸气剂泵。结果表明,氢是波导中的主要残余气体,Molflow +的模拟表明,新的泵送方案与原始配置相比,可使波导末端的压力降低了约5倍。新的腔对已在CEBAF中运行了431天,由于波导中存在真空峰值,因此总共只有3次跳闸。