【24h】

Design of a neutron camera for the HL-2A tokamak

机译:HL-2A托卡马克中子相机的设计

获取原文
获取原文并翻译 | 示例
           

摘要

A new neutron camera, comprising nine individual photo-multiplier tubes coupled with liquid scintillators through light guides, was designed, constructed and installed on the HL-2A tokamak. Using the HL-2A tokamak as an example, the basic principles for designing a camera system in low fusion power tokamaks were illustrated in this paper. The 2 '' x2 '' BC501A liquid scintillation detectors coupled with the gain stabilization system, were developed for neutron measurements and applied on the tokamak. A magnetic shielding system was designed, using the finite element method (FEM), to ensure excellent operation of detectors under a strong magnetic field. Energy calibration has been conducted and the light output function was compared with the PTB's values. The reasons for discrepancy and variations in the results are analyzed and discussed in detail in the paper.
机译:设计,建造并安装了一种新的中子相机,该相机由九个独立的光电倍增管和通过光导耦合的液体闪烁体组成,并安装在HL-2A托卡马克上。本文以HL-2A托卡马克为例,阐述了设计低聚变功率托卡马克相机系统的基本原理。 2''x2''BC501A液体闪烁探测器与增益稳定系统相结合,专为中子测量而开发,并应用于托卡马克上。使用有限元方法(FEM)设计了磁屏蔽系统,以确保检测器在强磁场下的出色运行。进行了能量校准,并将光输出功能与PTB的值进行了比较。本文分析并讨论了结果差异和差异的原因。