首页> 外文期刊>Nuclear Engineering and Design >Measurement of critical heat flux for narrow annuli submerged in saturated water
【24h】

Measurement of critical heat flux for narrow annuli submerged in saturated water

机译:浸入饱和水中的窄环的临界热通量的测量

获取原文
获取原文并翻译 | 示例
           

摘要

An experimental study has been performed to improve understanding of boiling phenomena and critical heat flux (CHF) in narrow gaps. The experiment has been performed with annular test sections submerged in a pool of saturated water under atmospheric pressure with the following conditions f outer diameter of inner tube of l9 mm; heated length of 200 mm; annular gap sizes of 0.5-3.5 mm, and inclination angles from horizontal to vertical positions. The experimental results reveal that the CHF increases with the gap size and the inclination angle. A one-dimensional two-phase model with a modified friction factor correlation is suggested to predict the CHF condition. The developed model is also compared with other CHF data.
机译:已经进行了一项实验研究,以增进对窄间隙中沸腾现象和临界热通量(CHF)的理解。实验是在以下条件下,将环形测试部分浸没在大气压下的饱和水中,其中的内管外径为19mm。加热长度为200毫米;环形间隙尺寸为0.5-3.5毫米,倾斜角度从水平位置到垂直位置。实验结果表明,CHF随间隙尺寸和倾斜角度的增加而增加。建议使用具有改进的摩擦系数相关性的一维两相模型来预测CHF条件。还将开发的模型与其他CHF数据进行比较。