Noise analysis is a valuable tool when applied to predictive maintenance problems in nuclear power plants. When focused to the capacitive pressure sensors it can detect the presence of undesirable bubbles in the sensing line. From the noise signal power spectrum density a resonant peak shifting towards the lower frequency region, due to bubbles appearance, is observed. In this work an explanation for the peak displacement is given, besides, a method to estimate the void fraction from the shift is developed. Both results benefit the on-line maintenance of pressure sensors without disturbing plant operation.
机译:将噪声分析应用于核电厂的预测性维护问题时,它是一种宝贵的工具。当聚焦于电容式压力传感器时,它可以检测到传感线中是否存在不希望有的气泡。从噪声信号功率谱密度中,观察到由于气泡的出现而向低频区域移动的共振峰。在这项工作中,给出了峰值位移的解释,此外,还开发了一种根据位移估算空隙率的方法。这两个结果都有利于压力传感器的在线维护,而不会影响工厂的运行。