Monotonic bending tests without internal pressure are conducted on 4 and 3.5 in. diameter full-scale carbon steel pipe specimens with local wall thinning in order to evaluate the structural integrity of power plant piping. The local wall thinning is simulated as erosion/corrosion metal loss. The eroded area of the wall thinning is subjected to tensile or compressive stress by applied bending moment. The maximum moments obtained from the tests are compared with the plastic collapse moments based on the net-section stress approach. The net-section stress approach based on flow stress σ_f gives a conservative estimation, sometimes overly conservative.