In order to remain economically effective and financially profitable, the modern industries have to take their safety culture to a higher level and consider production losses in addition to simple accident prevention techniques. Ideally, compliance with safety requirements start during early design stages, but in some older facilities provisions for Safety Instrumented Systems (SIS) may not have been originally included. In this paper, a case study of a Reheater Drains (RD) system is used to illustrate such an example. Frequent failures of tank level controller lead to transients where the operation of shutting down RD pumps requires operators to manually isolate the quenching water and to close the main steam admission valves. Water in this system is at saturation temperature for the reheater steam side pressure, and any manual operation of the system is highly undesirable due to hazards of working with wet steam at approximately 758 kPa(g) pressure, preheated to 237 degrees C. Additionally, losses of inventory are highly undesirable as well and challenge other systems in the plant. In this paper, it is suggested that RD system can benefit from installation of an independent SIS system in order to address current challenges. This idea is being explored using IEC 61508 framework for "Functional safety of electrical/electronic/programmable electronic safety-related systems" to provide assurance that the SIS will offer the necessary risk reduction required to achieve required safety for the equipment. (C) 2016 Elsevier B.V. All rights reserved.
机译:为了保持经济效益和经济效益,现代工业除了简单的事故预防技术外,还必须将其安全文化提高到更高的水平,并考虑生产损失。理想情况下,在早期设计阶段就开始符合安全要求,但是在某些较旧的设施中,最初可能并未包括安全仪表系统(SIS)的规定。在本文中,以再热器排水系统(RD)系统为例进行了说明。储罐液位控制器的频繁故障会导致瞬态变化,在这种情况下,关闭RD泵的操作需要操作员手动隔离淬火水并关闭主蒸汽入口阀。该系统中的水处于再加热器蒸汽侧压力的饱和温度,由于使用预热至237摄氏度的大约758 kPa(g)压力的湿蒸汽的危险,该系统的任何手动操作都是非常不希望的。此外,库存损失也是非常不希望的,并且会挑战工厂中的其他系统。在本文中,建议RD系统可以从安装独立的SIS系统中受益,以解决当前的挑战。正在使用“电气/电子/可编程电子安全相关系统的功能安全”的IEC 61508框架来探讨这一想法,以确保SIS将提供必要的风险降低,以实现设备所需的安全性。 (C)2016 Elsevier B.V.保留所有权利。

著录项

  • 来源
    《Nuclear Engineering and Design》 |2016年第5期|1-14|共14页
  • 作者单位

    Univ Ontario Inst Technol, Fac Energy Syst & Nucl Sci, 2000 Simcoe St N, Oshawa, ON L1H 7K4, Canada;

    Univ Ontario Inst Technol, Fac Energy Syst & Nucl Sci, 2000 Simcoe St N, Oshawa, ON L1H 7K4, Canada;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-18 00:41:47

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号