首页> 外文期刊>Nuclear Engineering and Design >Leak rate testing in the range of leak detection systems
【24h】

Leak rate testing in the range of leak detection systems

机译:泄漏检测系统范围内的泄漏率测试

获取原文
获取原文并翻译 | 示例
           

摘要

Leak-before-break assessments of piping in nuclear power plants require an accurate prediction of leakage rates through thin slits and the understanding of uncertainties. Two test rigs at the University of Stuttgart are dedicated to the measurement of flow rates in the order of the typical leak monitoring specification of 1 gal/min. Several hundred measurements of flow rates (single phase and two-phase) for different leak geometries and fluid conditions are performed, which fosters the data amount in this range significantly.Different established models for the prediction of leak flow rates have been applied and compared to the measured flow rates. The homogeneous data of the tests allows a quantitative understanding of the prediction uncertainties of the individual models. In the two-phase flow regime, about 90% of the tests are within 40% of deviation between measurement and computations, and for about 40% of the tests the deviation is even only 10% or less. By comparing five different models with different accuracy quantifications, the homogeneous equilibrium approaches with friction (Estorf model, Pana model) have the best overall result, while the Henry model has the worst one.
机译:核电厂管道的泄漏前评估需要通过薄的狭缝和对不确定因素的理解来准确地预测泄漏率。斯图加特大学的两台试验台致力于测量流量率为1 GAL / MIN的典型泄漏监测规格的顺序。执行不同泄漏几何形状和流体条件的数百次流速(单相和两相),这显着促进了该范围内的数据量。已经应用并比较了用于预测泄漏流速的预测模型。测量的流速。测试的均匀数据允许定量了解各个模型的预测不确定性。在两相流状态下,约90%的测试是在测量和计算之间偏差的40%以内,并且约40%的测试偏差甚至仅为10%或更少。通过比较具有不同精度量化的五种不同的型号,具有摩擦(Estorf Model,Pana模型)的均匀平衡方法具有最佳的整体结果,而亨利模型具有最糟糕的状态。

著录项

  • 来源
    《Nuclear Engineering and Design》 |2021年第2期|111000.1-111000.11|共11页
  • 作者单位

    Univ Stuttgart Inst Nucl Technol & Energy Syst IKE Pfaffenwaldring 31 D-70569 Stuttgart Germany;

    Univ Stuttgart Mat Testing Inst MPA Pfaffenwaldring 32 D-70569 Stuttgart Germany;

    Gesell Anlagen & Reaktorsicherheit GRS gGmbH Schwertnergasse 1 D-50667 Cologne Germany;

    Univ Stuttgart Inst Nucl Technol & Energy Syst IKE Pfaffenwaldring 31 D-70569 Stuttgart Germany;

    Univ Stuttgart Inst Nucl Technol & Energy Syst IKE Pfaffenwaldring 31 D-70569 Stuttgart Germany;

    Gesell Anlagen & Reaktorsicherheit GRS gGmbH Schwertnergasse 1 D-50667 Cologne Germany;

    Univ Stuttgart Mat Testing Inst MPA Pfaffenwaldring 32 D-70569 Stuttgart Germany;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Leak rate; Leak-before-break; Break preclusion;

    机译:泄漏率;泄漏前休息;断裂缩销;