Methods for measuring the current-voltage characteristics (I-V curves) of photodiodes in a 6 x 576 mercury-cadmium-tellurium (MCT) multirow photodetector designed for operation in the longwave part of the infrared (IR) spectral range are analyzed. The I-V curve is plotted using the resultes of measurements of output signals of a large-scale readout integrated circuit (ROIC) hybridized with a row of IR photodiodes. The method of independent current measurement at each point of the I-Vcurve is compared to the method of additive current measurements. A method of determining optimum working points of photodiodes by plotting and analyzing the dependence of the differential resistance of photodiode on the bias voltage is proposed. Distributions of photodiode currents for a sample of a 6 x 576-element focal plane array (FPA) based on MCT photodiodes with a p-type conductivity substrate having the cutoff wavelength of lambda(0.5) = 10.5 mu m are considered.
机译:分析了用于设计用于红外(IR)光谱范围的长波部分的6 x 576汞-镉-碲(MCT)多行光电探测器中光电二极管的电流-电压特性(I-V曲线)的测量方法。使用与一行红外光电二极管混合的大规模读出集成电路(ROIC)的输出信号的测量结果绘制I-V曲线。将I-Vcurve每个点的独立电流测量方法与加法电流测量方法进行比较。提出了一种通过绘制和分析光电二极管的差分电阻对偏置电压的依赖性来确定光电二极管最佳工作点的方法。考虑了基于MCT光电二极管的6 x 576元素焦平面阵列(FPA)的样品的光电二极管电流分布,该光电二极管带有截止波长为lambda(0.5)= 10.5μm的p型导电衬底。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号