The thickness of clay brick wall has been analyzed for comfortable room temperature in Bida town of Niger State(Latitude 9°8'). This comfortable room temperature is without the need to use air-conditioner. Conductive heat transfer analyses, with and without heat sources were made for unsteady state conditions to obtain a suitable thickness. To validate the result, a prototype structure of clay was built without windows. Experiment was performed using this prototype by keeping it in the sun throughout the day. The variation of temperature both inside and outside the prototype structure were recorded. The theoretical results were then compared with experimental results and were found to be in agreement. A brick thickness of 224.5mm was found to be suitable for building application.
机译:在尼日尔州比达镇(纬度9°8')对粘土砖墙的厚度进行了分析,以确保室温舒适。这种舒适的室温无需使用空调。针对非稳态条件进行了有热源和无热源的传导传热分析,以获得合适的厚度。为了验证结果,建造了没有窗户的粘土原型结构。使用该原型将其全天置于阳光下进行实验。记录原型结构内部和外部的温度变化。然后将理论结果与实验结果进行比较,发现结果是一致的。发现224.5mm的砖厚适合建筑应用。