首页> 外文期刊>Microgravity science and technology >Experimental Study of Weightless Effect on Small Vapor Compression Heat Pump
【24h】

Experimental Study of Weightless Effect on Small Vapor Compression Heat Pump

机译:小型蒸汽压缩热泵失重效应的实验研究

获取原文
获取原文并翻译 | 示例
           

摘要

Vapor compression heat pump is of great significance to space thermal control. It can effectively regulate the temperature of electronic devices to ensure proper operation. Weightlessness is a significant factor affecting the operation. Weightlessness test of vapor compression heat pump was conducted to investigate the weightless effect on its performance. Weightlessness test was achieved by free fall on a platform 60m above the ground. The tests of continuous weightlessness and single stroke of weightlessness were presented and analyzed. The results showed that the weightlessness decreased the evaporative heat transfer performance and enhanced the condensation heat transfer performance. It is then advisable to increase heat transfer area of the evaporator in the design of future vapor compression heat pumps, and the design of condensers could still be based on the routine method adopted in ground applications. This part of experimental data for space application of vapor compression heat pump is expected to be of great significance.
机译:蒸汽压缩热泵对空间热控制具有重要意义。它可以有效调节电子设备的温度,以确保正常运行。失重是影响操作的重要因素。进行蒸汽压缩热泵失重测试以研究失重对其性能的影响。失重测试是通过在地面以上60m的平台上自由落体实现的。提出并分析了连续失重和单次失重的测试。结果表明,失重降低了蒸发传热性能,增强了冷凝传热性能。因此建议在未来的蒸气压缩热泵的设计中增加蒸发器的传热面积,而冷凝器的设计仍可以基于地面应用中采用的常规方法。蒸汽压缩热泵在空间应用中的这部分实验数据有望具有重要意义。